Certificate Options

Davis Calibration offers flexible calibration options to meet your exact requirements.

  • Without Data: Instrumentation is calibrated to manufacture specifications with NIST traceable standards in full compliance of ANSI Z540-1. Full data is reported if instrument is found out of tolerance.

  • With Data (Before/After Data): Instrumentation is calibrated to manufacture specifications with NIST traceable standards in full compliance of ANSI Z540-1. Full Before/After Data Report is recorded and shown on the calibration certificate.

  • 17025 Calibration Service: Instrumentation is calibrated in accordance with ISO/IEC 17025 with one of the following two options:

    • ISO/IEC 17025 without uncertainties: Instrument is calibrated within our approved scope of accreditation including full before/after data reporting.

    • ISO/IEC 17025 with uncertainties: Instrument is calibrated within our approved scope of accreditation including full before/after data reporting and associated uncertainties of measurement reporting.


  •                                                 Certificate Options

     

    Without
    Before/
    After
    Data

    With
    Before/
    After Data

    Accredited
    17025

    Accredited 17025
    With
    Uncertainties

    ANSI Z540-1 Compliant

    X

    X

    X

    X

    ISO 9000:2001 Certification

    X

    X

    X

    X

    ISO/IEC 17025 Compliant Calibration

    X

    X

    X

    X

    ISO/IEC 17025 Accredited Calibration

     

     

    X

    X

    NIST Traceable Calibration

    X

    X

    X

    X

    Min. 4:1 Test Uncertainty Ratio (TUR)¹

    X

    X

    X

    X

    Out of Tolerance (OOT) Notification

    X

    X

    X

    X

    As Found/As Left Test Data

     OOT²

    X

    X

    X

    Adjustments to Manufacture Specs³

    X

    X

    X

    X

    Online Electronic Certificate (DATA)

    X

    X

    X

    X

    Test Point Specific Uncertainty Data

     

     

     

    X

    Notes:
    1
    - Exceptions of 4:1 TUR will be stated at the time we quote service

    2
    - If found OOT
    3
    - No charge for adjustments when made by Davis Calibration

Each certification option is available with any of our calibration services:

> Standard 5-Day Pick-Up & Return Service
> Express 3-Day Pick-Up & Return Service
> On-Site Service